A3 (8Y) – Door lock/unlock confirmation (Beep/Horn) (Coding)

A3 (8Y) – Door lock/unlock confirmation (Beep/Horn) (Coding)
A3 (8Y) – Door lock/unlock confirmation (Beep/Horn) (Coding)

Purpose: Allows you to configure the door locking/unlocking confirmation with Beep (alarm) or Horn.

Attention!! There are 9 coding lines to do here.

Proceed:
1 – Engine off, ignition off, connect your official VAG-COM VCDS cable to the computer then connect the other end to the diagnostic socket of your vehicle or your OBDeleven box.

2 – Switch on the ignition then launch the VCDS program or the OBDeleven application.

 

On the first button click:

Line 1:

3 – Click on “  Select  ” then click on “  09- Power station ”.

4 – Click on “  Security Access – 16  ” then type the code “  31347 ” 

5 – Click on “  Adaptation – 10 ”.

6 – On this page, at the very top, there is a drop-down menu.
In this drop-down menu, choose “  Komfort_quittung ” 

7 – On this same page, there is a second drop-down menu but towards the bottom
of the page.
On the latter, choose “  active  ” then validate.

Line 2:

3 – Click on “  Select  ” then click on “  09- Power station ”.

4 – Click on “  Security Access – 16  ” then type the code “  31347 ” 

5 – Click on “  Adaptation – 10 ”.

6 – On this page, at the very top, there is a drop-down menu.
In this drop-down menu, choose “  Quittungston_ueber_hupe ” 

7 – On this same page, there is a second drop-down menu but towards the bottom
of the page.
On this last one, choose “  active  ” then validate.

Line 3:

3 – Click on “  Select  ” then click on “  09- Power station ”.

4 – Click on “  Security Access – 16  ” then type the code “  31347 ” 

5 – Click on “  Adaptation – 10 ”.

6 – On this page, at the very top, there is a drop-down menu.
In this drop-down menu, choose “  Akustische Quittierungsdauer Einfachhorn ” 

7 – On this same page, there is a second drop-down menu but towards the bottom
of the page.
On this last one, choose “  normal  ” or “  kurz  ” (for a short signal) then validate.

Line 4:

3 – Click on “  Select  ” then click on “  09- Power station ”.

4 – Click on “  Security Access – 16  ” then type the code “  31347 ” 

5 – Click on “  Adaptation – 10 ”.

6– On this page, at the very top, there is a drop-down menu.
In this drop-down menu, choose “  Quittierton_global ” 

7 – On this same page, there is a second drop-down menu but towards the bottom
of the page.
On this last one, choose “  active  ” then validate.

Line 5:

3 – Click on “  Select  ” then click on “  09- Power plant ”.

4 – Click on “  Security Access – 16  ” then type the code “  31347 ” 

5 – Click on “  Adaptation – 10 ”.

6 – On this page, at the very top, there is a drop-down menu.
In this drop-down menu, choose “  Quittungston_hmi_einstellbar ” 

7 – On this same page, there is a second drop-down menu but towards the bottom
of the page.
On this last one, choose “  active  ” then validate.

 

Line 6:

3 – Click on “  Select  ” then click on “  09- Power station ”.

4 – Click on “  Security Access – 16  ” then type the code “  31347 ” 

5 – Click on “  Adaptation – 10 ”.

6 – On this page, at the very top, there is a drop-down menu.
In this drop-down menu, choose “  Quittierungston_bei_entriegeln ” 

7 – On this same page there is a second drop-down menu but towards the bottom
of the page.
On the latter, choose “  active  ” then validate.

 

Line 7:

3 – Click on “  Select  ” then click on “  09- Power station ”.

4 – Click on “  Security Access – 16  ” then type the code “  31347 ” 

5 – Click on “  Adaptation – 10 ”.

6 – On this page, at the very top, there is a drop-down menu.
In this drop-down menu, choose “  Quittungs _ton_bei_verriegen ” 

7 – On this same page there is a second drop-down menu but towards the bottom
of the page.
On the latter, choose “  active  ” then validate.

On the second click of the button:

Line 8:

3 – Click on “  Select  ” then click on “  09- Power station ”.

4 – Click on “  Security Access – 16  ” then type the code “  31347 ” 

5 – Click on “  Adaptation – 10 ”.

6 – On this page, at the very top, there is a drop-down menu.
In this drop-down menu, choose “  Quittungs_beim_zweiten_ZV_AUF_Befehl ” 

7 – On this same page there is a second drop-down menu but towards the bottom
of the page.
On the latter, choose “  active  ” then validate.

 

Line 9:

3 – Click on “  Select  ” then click on “  09- Power station ”.

4 – Click on “  Security Access – 16  ” then type the code “  31347 ” 

5 – Click on “  Adaptation – 10 ”.

6 – On this page, at the very top, there is a drop-down menu.
In this drop-down menu, choose “  Quittungs _beim _zweiten_ZV_ZU_Befehl ” 

7 – On this same page there is a second drop-down menu but towards the bottom
of the page.
On the latter, choose “  active  ” then validate.